Posts

Showing posts from November, 2022

References

  J. R. Lamarsh, Introduction to Nuclear Reactor Theory, 2nd ed., Addison-Wesley, Reading, MA (1983). J. R. Lamarsh, A. J. Baratta, Introduction to Nuclear Engineering, 3d ed., Prentice-Hall, 2001, ISBN: 0-201-82498-1. W. M. Stacey, Nuclear Reactor Physics, John Wiley & Sons, 2001, ISBN: 0- 471-39127-1. Glasstone, Sesonske. Nuclear Reactor Engineering: Reactor Systems Engineering, Springer; 4th edition, 1994, ISBN: 978-0412985317

Comparison Of Dosimeter Type

Image
 

Components of Eureka Lab shielding

  Brand: Wolf u   Lead glass: 2mm thickness u   Material of shielding barrier: Stainless   Steel u   Attenuation Coefficient of Steel:   The linear attenuation coefficient of stainless steel for the 60 Co source is  0.426 cm −1 , thus the gamma attenuation in a 0.5 mm steel plate is ∼ 2%; nonetheless, the actual attenuation is even lower due to the multihole structure.   https://cdn.shopify.com/s/files/1/1658/0223/products/MY_SHIELD_56612_530x.JPG?v=1558342896

Monthly Read-Off With OEP Annual Dose Limit At Eureka Lab

Image
Standa d Annual Dose Lim its for OEPs An nual Dose OEP at Eureka Received 20 

Proposed Optimized Shielding Plan For EUREKA LAB

    1 Sliding Stainless Steel Door Purpose The double door's hinges will eventually loosen, which will cause photons energy from the X-Ray tube to be expelled via the door's crease. NOTE : Both patients and medical personnel may be at risk from this.

CONT’D

    Purpose u   Development of a Toilet As the X-Ray department is now switching from analog to digital radiology, the current storage room would be empty. u   Justification for picking this location : Plumbing fixtures, such as pipes, are directly accessible. A bathroom is necessary to maintain good hygiene and stop the spread of disease.

Proposed Optimized Shielding Plan For New Amsterdam Hospital

Image
         Construction Of a washroom:       12 sack cement at 1900= 22800 2 tone sand àt 2500 = 5000 4"x 8"x 16" concrete block at 120= 12000 1 toilet bowl 29000= 29000 1face basin 8000= 8000 1 steel door 280000=280000   Labour cost 250000  

Cover Page

Image
                                                          Radiation Protection BMI2106              GROUP MEMBERS: LIVIONA WATTS- 1040402                                     RONELLA MCPHERSON- 1040399                                     NIOCY FRASER -1041262                                    CAMISA CHISHOLM -1041398                                   SHAQUILLE PATRICK- 1028706 TOPIC: STRUCTURAL SHIELDING LECTURE: MS. PETAL SURU...